          24: One more problem. The
        
        
          first train made it all the way
        
        
          through South Jackson and
        
        
          was entering Mill Bend when
        
        
          “beep beep beep”, we had
        
        
          another short.
        
        
          The South Jackson and Mill
        
        
          Bend blocks are powered
        
        
          by two different boosters.
        
        
          When the loco bridged the
        
        
          boundary a short occurred.
        
        
          A quick check with a digital
        
        
          multi-meter revealed the two
        
        
          blocks had opposite polarity
        
        
          rail power.
        
        
          It appears that when a
        
        
          Digitrax DCS-100 and
        
        
          DB-150 are run off a com-
        
        
          mon LocoNet, the Rail A
        
        
          and B outpus of the DB150
        
        
          are reversed from the Rail
        
        
          A and B outputs of the
        
        
          DCS100. When the loco con-
        
        
          nected them, a short circuit
        
        
          occurred.
        
        
          I swapped the Rail A and B
        
        
          wires on the DB150 and all
        
        
          was well again.
        
        
          All I can say is “I’mworking
        
        
          on it” and things are looking
        
        
          promising.
        
        
          Time will tell.
        
        
          
        
        
        
        
        
          
            24